{"id":10727,"date":"2025-10-19T11:02:35","date_gmt":"2025-10-19T11:02:35","guid":{"rendered":"https:\/\/madeventeg.com\/?post_type=product&#038;p=10727"},"modified":"2025-10-19T11:02:35","modified_gmt":"2025-10-19T11:02:35","slug":"hka-315m-centrifugal-c-2334","status":"publish","type":"product","link":"https:\/\/madeventeg.com\/index.php\/product\/hka-315m-centrifugal-c-2334\/","title":{"rendered":"HKA 315M CENTRIFUGAL (C-2334)"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_column_text]<\/p>\n<h3 data-start=\"255\" data-end=\"285\">\ud83d\udd39 <strong data-start=\"262\" data-end=\"285\">GENERAL DESCRIPTION<\/strong><\/h3>\n<p data-start=\"287\" data-end=\"535\">The <strong data-start=\"291\" data-end=\"346\">HKA Industrial Radial Fans \u2013 Backward Curved Series<\/strong> are <strong data-start=\"351\" data-end=\"382\">heavy-duty centrifugal fans<\/strong> specifically engineered for <strong data-start=\"411\" data-end=\"477\">industrial ventilation, air movement, and process applications<\/strong> requiring high efficiency, reliability, and durability.<\/p>\n<p data-start=\"537\" data-end=\"826\">These fans are designed with <strong data-start=\"566\" data-end=\"595\">backward-curved impellers<\/strong> that provide <strong data-start=\"609\" data-end=\"645\">superior aerodynamic performance<\/strong>, high static pressure, and low noise levels. The backward-curved blade profile minimizes dust accumulation and enhances efficiency compared to traditional forward-curved designs.<\/p>\n<p data-start=\"828\" data-end=\"1032\">Constructed from <strong data-start=\"845\" data-end=\"868\">robust welded steel<\/strong> and coated with <strong data-start=\"885\" data-end=\"927\">epoxy or hot-dip galvanized protection<\/strong>, the HKA fans are capable of operating under harsh industrial environments and continuous duty cycles.<\/p>\n<p data-start=\"1034\" data-end=\"1261\">The fan assembly consists of a <strong data-start=\"1065\" data-end=\"1096\">precision-balanced impeller<\/strong>, a <strong data-start=\"1100\" data-end=\"1125\">heavy-duty base frame<\/strong>, and a <strong data-start=\"1133\" data-end=\"1147\">TEFC motor<\/strong> mounted either <strong data-start=\"1163\" data-end=\"1175\">directly<\/strong> on the shaft or via a <strong data-start=\"1198\" data-end=\"1219\">belt-drive system<\/strong>, depending on performance requirements.<\/p>\n<p data-start=\"1263\" data-end=\"1441\">The <strong data-start=\"1267\" data-end=\"1306\">modular and service-friendly design<\/strong> allows easy access to internal components for inspection and maintenance, ensuring long-term reliability and consistent performance.<\/p>\n<p data-start=\"1443\" data-end=\"1707\">Thanks to their <strong data-start=\"1459\" data-end=\"1479\">rugged structure<\/strong>, <strong data-start=\"1481\" data-end=\"1525\">energy-efficient airflow characteristics<\/strong>, and <strong data-start=\"1531\" data-end=\"1559\">versatile configurations<\/strong>, HKA Industrial Radial Fans are widely used in <strong data-start=\"1607\" data-end=\"1693\">factories, workshops, HVAC systems, dust extraction units, and process ventilation<\/strong> applications.<\/p>\n<hr data-start=\"1709\" data-end=\"1712\" \/>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text woodmart_inline=&#8221;no&#8221; text_larger=&#8221;no&#8221;]<\/p>\n<h3 data-start=\"427\" data-end=\"479\">\ud83e\udde9 <strong data-start=\"434\" data-end=\"479\">1. FAN COMPONENTS AND MATERIAL PROPERTIES<\/strong><\/h3>\n<div class=\"_tableContainer_1rjym_1\">\n<div class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"481\" data-end=\"1869\">\n<thead data-start=\"481\" data-end=\"528\">\n<tr data-start=\"481\" data-end=\"528\">\n<th data-start=\"481\" data-end=\"493\" data-col-size=\"sm\">Component<\/th>\n<th data-start=\"493\" data-end=\"507\" data-col-size=\"lg\">Description<\/th>\n<th data-start=\"507\" data-end=\"528\" data-col-size=\"md\">Material \/ Finish<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"579\" data-end=\"1869\">\n<tr data-start=\"579\" data-end=\"766\">\n<td data-start=\"579\" data-end=\"597\" data-col-size=\"sm\"><strong data-start=\"581\" data-end=\"596\">Fan Housing<\/strong><\/td>\n<td data-col-size=\"lg\" data-start=\"597\" data-end=\"685\">Sturdy welded steel casing designed to handle high pressure and continuous operation.<\/td>\n<td data-col-size=\"md\" data-start=\"685\" data-end=\"766\">Mild steel or galvanized steel, epoxy powder coated for corrosion resistance.<\/td>\n<\/tr>\n<tr data-start=\"767\" data-end=\"976\">\n<td data-start=\"767\" data-end=\"790\" data-col-size=\"sm\"><strong data-start=\"769\" data-end=\"789\">Impeller (Wheel)<\/strong><\/td>\n<td data-col-size=\"lg\" data-start=\"790\" data-end=\"906\">Backward-curved radial impeller with high static efficiency and self-cleaning blade design, dynamically balanced.<\/td>\n<td data-col-size=\"md\" data-start=\"906\" data-end=\"976\">Mild steel or stainless steel, epoxy coated or hot-dip galvanized.<\/td>\n<\/tr>\n<tr data-start=\"977\" data-end=\"1137\">\n<td data-start=\"977\" data-end=\"989\" data-col-size=\"sm\"><strong data-start=\"979\" data-end=\"988\">Motor<\/strong><\/td>\n<td data-start=\"989\" data-end=\"1077\" data-col-size=\"lg\">High-performance industrial motor designed for heavy-duty and continuous duty cycles.<\/td>\n<td data-col-size=\"md\" data-start=\"1077\" data-end=\"1137\">IP55, Class F insulation, available in 2, 4, or 6 poles.<\/td>\n<\/tr>\n<tr data-start=\"1138\" data-end=\"1309\">\n<td data-start=\"1138\" data-end=\"1157\" data-col-size=\"sm\"><strong data-start=\"1140\" data-end=\"1156\">Drive System<\/strong><\/td>\n<td data-col-size=\"lg\" data-start=\"1157\" data-end=\"1261\">Available as direct drive or belt drive configuration depending on airflow and pressure requirements.<\/td>\n<td data-col-size=\"md\" data-start=\"1261\" data-end=\"1309\">Cast iron pulleys and high-strength V-belts.<\/td>\n<\/tr>\n<tr data-start=\"1310\" data-end=\"1442\">\n<td data-start=\"1310\" data-end=\"1337\" data-col-size=\"sm\"><strong data-start=\"1312\" data-end=\"1336\">Base Frame \/ Support<\/strong><\/td>\n<td data-col-size=\"lg\" data-start=\"1337\" data-end=\"1401\">Heavy-duty steel frame ensures rigidity and stable operation.<\/td>\n<td data-col-size=\"md\" data-start=\"1401\" data-end=\"1442\">Welded steel, anti-vibration mounted.<\/td>\n<\/tr>\n<tr data-start=\"1443\" data-end=\"1584\">\n<td data-start=\"1443\" data-end=\"1469\" data-col-size=\"sm\"><strong data-start=\"1445\" data-end=\"1468\">Inlet Cone \/ Flange<\/strong><\/td>\n<td data-col-size=\"lg\" data-start=\"1469\" data-end=\"1550\">Aerodynamically shaped inlet cone for smooth air entry and reduced turbulence.<\/td>\n<td data-col-size=\"md\" data-start=\"1550\" data-end=\"1584\">Galvanized or stainless steel.<\/td>\n<\/tr>\n<tr data-start=\"1585\" data-end=\"1719\">\n<td data-start=\"1585\" data-end=\"1600\" data-col-size=\"sm\"><strong data-start=\"1587\" data-end=\"1599\">Bearings<\/strong><\/td>\n<td data-col-size=\"lg\" data-start=\"1600\" data-end=\"1685\">High-quality ball or roller bearings for long service life under industrial loads.<\/td>\n<td data-col-size=\"md\" data-start=\"1685\" data-end=\"1719\">Sealed type, maintenance-free.<\/td>\n<\/tr>\n<tr data-start=\"1720\" data-end=\"1869\">\n<td data-start=\"1720\" data-end=\"1744\" data-col-size=\"sm\"><strong data-start=\"1722\" data-end=\"1743\">Vibration Dampers<\/strong><\/td>\n<td data-col-size=\"lg\" data-start=\"1744\" data-end=\"1821\">Rubber or spring isolators minimize vibration and structural transmission.<\/td>\n<td data-col-size=\"md\" data-start=\"1821\" data-end=\"1869\">Industrial-grade elastomer or steel springs.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"1871\" data-end=\"1874\" \/>\n<h3 data-start=\"1876\" data-end=\"1904\">\ud83c\udfd7\ufe0f <strong data-start=\"1884\" data-end=\"1904\">2. FAN STRUCTURE<\/strong><\/h3>\n<ul data-start=\"1906\" data-end=\"2677\">\n<li data-start=\"1906\" data-end=\"2082\">\n<p data-start=\"1908\" data-end=\"2082\"><strong data-start=\"1908\" data-end=\"1938\">Centrifugal Radial Design:<\/strong><br data-start=\"1938\" data-end=\"1941\" \/>Air enters axially and is discharged radially at 90\u00b0, generating high static pressure suitable for ducted systems and industrial processes.<\/p>\n<\/li>\n<li data-start=\"2084\" data-end=\"2249\">\n<p data-start=\"2086\" data-end=\"2249\"><strong data-start=\"2086\" data-end=\"2115\">Backward-Curved Impeller:<\/strong><br data-start=\"2115\" data-end=\"2118\" \/>Engineered to provide higher efficiency, lower power consumption, and reduced dust accumulation compared to forward-curved types.<\/p>\n<\/li>\n<li data-start=\"2251\" data-end=\"2414\">\n<p data-start=\"2253\" data-end=\"2414\"><strong data-start=\"2253\" data-end=\"2284\">Robust Welded Construction:<\/strong><br data-start=\"2284\" data-end=\"2287\" \/>The entire fan casing and base frame are made from thick-gauge steel, ensuring mechanical strength and long operational life.<\/p>\n<\/li>\n<li data-start=\"2416\" data-end=\"2534\">\n<p data-start=\"2418\" data-end=\"2534\"><strong data-start=\"2418\" data-end=\"2456\">Inspection and Maintenance Access:<\/strong><br data-start=\"2456\" data-end=\"2459\" \/>Equipped with removable inspection doors for easy cleaning and servicing.<\/p>\n<\/li>\n<li data-start=\"2536\" data-end=\"2677\">\n<p data-start=\"2538\" data-end=\"2677\"><strong data-start=\"2538\" data-end=\"2572\">Flexible Installation Options:<\/strong><br data-start=\"2572\" data-end=\"2575\" \/>Can be mounted horizontally or vertically, with inlet\/outlet positions adaptable to the duct layout.<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"2679\" data-end=\"2682\" \/>\n<h3 data-start=\"2684\" data-end=\"2711\">\ud83c\udf1f <strong data-start=\"2691\" data-end=\"2711\">3. MAIN BENEFITS<\/strong><\/h3>\n<ul data-start=\"2713\" data-end=\"3364\">\n<li data-start=\"2713\" data-end=\"2809\">\n<p data-start=\"2715\" data-end=\"2809\"><strong data-start=\"2715\" data-end=\"2734\">High efficiency<\/strong> airflow and pressure performance due to backward-curved impeller design.<\/p>\n<\/li>\n<li data-start=\"2810\" data-end=\"2914\">\n<p data-start=\"2812\" data-end=\"2914\"><strong data-start=\"2812\" data-end=\"2852\">Suitable for industrial applications<\/strong> requiring reliable air movement under high static pressure.<\/p>\n<\/li>\n<li data-start=\"2915\" data-end=\"3005\">\n<p data-start=\"2917\" data-end=\"3005\"><strong data-start=\"2917\" data-end=\"2944\">Heavy-duty construction<\/strong> ensures long lifespan and resistance to mechanical stress.<\/p>\n<\/li>\n<li data-start=\"3006\" data-end=\"3082\">\n<p data-start=\"3008\" data-end=\"3082\"><strong data-start=\"3008\" data-end=\"3042\">Low vibration and noise levels<\/strong> achieved through precision balancing.<\/p>\n<\/li>\n<li data-start=\"3083\" data-end=\"3150\">\n<p data-start=\"3085\" data-end=\"3150\"><strong data-start=\"3085\" data-end=\"3118\">Self-cleaning impeller blades<\/strong> reduce maintenance frequency.<\/p>\n<\/li>\n<li data-start=\"3151\" data-end=\"3229\">\n<p data-start=\"3153\" data-end=\"3229\"><strong data-start=\"3153\" data-end=\"3182\">Weather-resistant coating<\/strong> suitable for indoor or outdoor installation.<\/p>\n<\/li>\n<li data-start=\"3230\" data-end=\"3296\">\n<p data-start=\"3232\" data-end=\"3296\"><strong data-start=\"3232\" data-end=\"3265\">Flexible drive configurations<\/strong> to suit system requirements.<\/p>\n<\/li>\n<li data-start=\"3297\" data-end=\"3364\">\n<p data-start=\"3299\" data-end=\"3364\"><strong data-start=\"3299\" data-end=\"3319\">Easy integration<\/strong> with filters, dampers, and ducted systems.<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"3366\" data-end=\"3369\" \/>\n<h3 data-start=\"3371\" data-end=\"3398\">\u2699\ufe0f <strong data-start=\"3378\" data-end=\"3398\">4. SPEED CONTROL<\/strong><\/h3>\n<ul data-start=\"3400\" data-end=\"3854\">\n<li data-start=\"3400\" data-end=\"3542\">\n<p data-start=\"3402\" data-end=\"3542\"><strong data-start=\"3402\" data-end=\"3437\">Variable Frequency Drive (VFD):<\/strong><br data-start=\"3437\" data-end=\"3440\" \/>Enables precise adjustment of fan speed and airflow, optimizing performance and energy efficiency.<\/p>\n<\/li>\n<li data-start=\"3543\" data-end=\"3654\">\n<p data-start=\"3545\" data-end=\"3654\"><strong data-start=\"3545\" data-end=\"3584\">Pulley Adjustment (for Belt Drive):<\/strong><br data-start=\"3584\" data-end=\"3587\" \/>Fan speed can be manually adjusted by varying pulley diameters.<\/p>\n<\/li>\n<li data-start=\"3655\" data-end=\"3769\">\n<p data-start=\"3657\" data-end=\"3769\"><strong data-start=\"3657\" data-end=\"3691\">Multi-Speed Motors (Optional):<\/strong><br data-start=\"3691\" data-end=\"3694\" \/>Available for systems requiring two or three selectable speed settings.<\/p>\n<\/li>\n<li data-start=\"3770\" data-end=\"3854\">\n<p data-start=\"3772\" data-end=\"3854\"><strong data-start=\"3772\" data-end=\"3790\">Soft Starters:<\/strong><br data-start=\"3790\" data-end=\"3793\" \/>Reduce inrush current and mechanical stress during startup.<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"3856\" data-end=\"3859\" \/>\n<h3 data-start=\"3861\" data-end=\"3886\">\ud83c\udfed <strong data-start=\"3868\" data-end=\"3886\">5. USAGE AREAS<\/strong><\/h3>\n<p data-start=\"3888\" data-end=\"4012\"><strong data-start=\"3888\" data-end=\"3943\">HKA Industrial Radial Fans \u2013 Backward Curved Series<\/strong> are suitable for a wide range of heavy-duty applications, including:<\/p>\n<ul data-start=\"4014\" data-end=\"4717\">\n<li data-start=\"4014\" data-end=\"4115\">\n<p data-start=\"4016\" data-end=\"4115\">\ud83c\udfed <strong data-start=\"4019\" data-end=\"4054\">Industrial Ventilation Systems:<\/strong><br data-start=\"4054\" data-end=\"4057\" \/>Factories, workshops, foundries, and production halls.<\/p>\n<\/li>\n<li data-start=\"4117\" data-end=\"4206\">\n<p data-start=\"4119\" data-end=\"4206\">\ud83d\udd25 <strong data-start=\"4122\" data-end=\"4150\">Smoke &amp; Fume Extraction:<\/strong><br data-start=\"4150\" data-end=\"4153\" \/>Removal of hot gases, fumes, and welding exhaust.<\/p>\n<\/li>\n<li data-start=\"4208\" data-end=\"4315\">\n<p data-start=\"4210\" data-end=\"4315\">\ud83c\udf21\ufe0f <strong data-start=\"4214\" data-end=\"4246\">HVAC &amp; Process Air Handling:<\/strong><br data-start=\"4246\" data-end=\"4249\" \/>Integration with ducted ventilation and air treatment systems.<\/p>\n<\/li>\n<li data-start=\"4317\" data-end=\"4424\">\n<p data-start=\"4319\" data-end=\"4424\">\ud83c\udf7d\ufe0f <strong data-start=\"4323\" data-end=\"4365\">Commercial Kitchens &amp; Exhaust Systems:<\/strong><br data-start=\"4365\" data-end=\"4368\" \/>High-pressure extraction of grease-laden or hot air.<\/p>\n<\/li>\n<li data-start=\"4426\" data-end=\"4536\">\n<p data-start=\"4428\" data-end=\"4536\">\u2699\ufe0f <strong data-start=\"4431\" data-end=\"4470\">Dust Collection &amp; Filtration Units:<\/strong><br data-start=\"4470\" data-end=\"4473\" \/>Ideal for conveying air in filtration and baghouse systems.<\/p>\n<\/li>\n<li data-start=\"4538\" data-end=\"4622\">\n<p data-start=\"4540\" data-end=\"4622\">\ud83e\uddf1 <strong data-start=\"4543\" data-end=\"4579\">Boiler and Furnace Applications:<\/strong><br data-start=\"4579\" data-end=\"4582\" \/>Supply or exhaust of combustion air.<\/p>\n<\/li>\n<li data-start=\"4624\" data-end=\"4717\">\n<p data-start=\"4626\" data-end=\"4717\">\ud83d\udeaa <strong data-start=\"4629\" data-end=\"4665\">Paint Booths &amp; Industrial Rooms:<\/strong><br data-start=\"4665\" data-end=\"4668\" \/>Controlled ventilation and air renewal systems.<\/p>\n<\/li>\n<li data-start=\"4624\" data-end=\"4717\">\n<h3 data-start=\"100\" data-end=\"135\">\u2699\ufe0f <strong data-start=\"107\" data-end=\"135\">Technical Specifications<\/strong><\/h3>\n<ul data-start=\"137\" data-end=\"376\">\n<li data-start=\"137\" data-end=\"159\">\n<p data-start=\"139\" data-end=\"159\"><strong data-start=\"139\" data-end=\"151\">Voltage:<\/strong> 230 V<\/p>\n<\/li>\n<li data-start=\"160\" data-end=\"184\">\n<p data-start=\"162\" data-end=\"184\"><strong data-start=\"162\" data-end=\"176\">Frequency:<\/strong> 50 Hz<\/p>\n<\/li>\n<li data-start=\"185\" data-end=\"206\">\n<p data-start=\"187\" data-end=\"206\"><strong data-start=\"187\" data-end=\"197\">Power:<\/strong> 0.25 KW<\/p>\n<\/li>\n<li data-start=\"207\" data-end=\"229\">\n<p data-start=\"209\" data-end=\"229\"><strong data-start=\"209\" data-end=\"221\">Current:<\/strong> 2.1 A<\/p>\n<\/li>\n<li data-start=\"230\" data-end=\"253\">\n<p data-start=\"232\" data-end=\"253\"><strong data-start=\"232\" data-end=\"242\">Speed:<\/strong> 1380 RPM<\/p>\n<\/li>\n<li data-start=\"254\" data-end=\"281\">\n<p data-start=\"256\" data-end=\"281\"><strong data-start=\"256\" data-end=\"269\">Air Flow:<\/strong> 1800 m\u00b3\/h<\/p>\n<\/li>\n<li data-start=\"282\" data-end=\"322\">\n<p data-start=\"284\" data-end=\"322\"><strong data-start=\"284\" data-end=\"309\">Sound Pressure Level:<\/strong> 29-37 dB<\/p>\n<\/li>\n<li data-start=\"323\" data-end=\"354\">\n<p data-start=\"325\" data-end=\"354\"><strong data-start=\"325\" data-end=\"346\">Protection Class:<\/strong> IP 55<\/p>\n<\/li>\n<li data-start=\"355\" data-end=\"376\">\n<p data-start=\"357\" data-end=\"376\"><strong data-start=\"357\" data-end=\"368\">Weight:<\/strong> 41 kg<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<hr data-start=\"4719\" data-end=\"4722\" \/>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text] \ud83d\udd39 GENERAL DESCRIPTION The HKA Industrial Radial Fans \u2013 Backward Curved Series are heavy-duty centrifugal fans specifically engineered for<\/p>\n","protected":false},"featured_media":10728,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[69],"product_tag":[],"class_list":{"0":"post-10727","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-radial-fans","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/madeventeg.com\/index.php\/wp-json\/wp\/v2\/product\/10727","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/madeventeg.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/madeventeg.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/madeventeg.com\/index.php\/wp-json\/wp\/v2\/comments?post=10727"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/madeventeg.com\/index.php\/wp-json\/wp\/v2\/media\/10728"}],"wp:attachment":[{"href":"https:\/\/madeventeg.com\/index.php\/wp-json\/wp\/v2\/media?parent=10727"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/madeventeg.com\/index.php\/wp-json\/wp\/v2\/product_brand?post=10727"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/madeventeg.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=10727"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/madeventeg.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=10727"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}